Background: Amnioinfusion aims to prevent or relieve umbilical cord compression during labour by infusing a solution into the uterine cavity. It is also thought to dilute meconium when present in the amniotic fluid and so reduce the risk of meconium aspiration. However, it may be that the mechanism of effect is that it corrects oligohydramnios (reduced amniotic fluid), for which thick meconium staining is a marker.

Objectives: The objective of this review was to assess the effects of amnioinfusion for meconium-stained liquor on perinatal outcome.

Search strategy: The Cochrane Pregnancy and Childbirth Group trials register (October 2001) and the Cochrane Controlled Trials Register (Issue 3, 2001) were searched.

Selection criteria: Randomised trials comparing amnioinfusion with no amnioinfusion for women in labour with moderate or thick meconium-staining of the amniotic fluid.

Data collection and analysis: Eligibility and trial quality were assessed by one reviewer.

Main results: Twelve studies, most involving small numbers of participants, were included. Under standard perinatal surveillance, amnioinfusion was associated with a reduction in the following: heavy meconium staining of the liquor (relative risk 0.03, 95% confidence interval 0.01 to 0.15); variable fetal heart rate deceleration (relative risk 0.65, 95% confidence interval 0.49 to 0.88); and reduced caesarean section overall (relative risk 0.82, 95% confidence interval 0.69 to 1.97). No perinatal deaths were reported. Under limited perinatal surveillance, amnioinfusion was associated with a reduction in the following: meconium aspiration syndrome (relative risk 0.24, 95% confidence interval 0.12 to 0.48); neonatal hypoxic ischaemic encephalopathy (relative risk 0.07, 95% confidence interval 0.01 to 0.56) and neonatal ventilation or intensive care unit admission (relative risk 0.56, 95% confidence interval 0.39 to 0.79); there was a trend towards reduced perinatal mortality (relative risk 0.34, 95% confidence interval 0.11 to 1.06).

Reviewers' conclusions: Amnioinfusion is associated with improvements in perinatal outcome, particularly in settings where facilities for perinatal surveillance are limited. The trials reviewed are too small to address the possibility of rare but serious maternal adverse effects of amnioinfusion.

Citation: Hofmeyr GJ. Amnioinfusion for meconium-stained liquor in labour (Cochrane Review). In: The Cochrane Library, Issue 3, 2003. Oxford: Update Software.



This is an abstract of a regularly updated, systematic review prepared and maintained by the Cochrane Collaboration. The full text of the review is available in The Cochrane Library (ISSN 1464-780X).

The Cochrane Library is designed and produced by Update Software Ltd.

Update Software Ltd, Summertown Pavilion, Middle Way, Oxford OX2 7LG, UK
(Tel:+44 1865 513902; Fax:+44 1865 516918)

File Reference: AB000014.htm